Camcorp SWF with Internally Mounted Fan Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Camcorp SWF with Internally Mounted Fan. CAMCORP SWF with Internally Mounted Fan User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - DUST COLLECTOR BAGHOUSE

REVERSE AIR - MODEL SWF DUST COLLECTOR BAGHOUSE INSTRUCTION, OPERATIONS & MAINTENANCE MANUALCAMCORP, INC. Phone: 913-831-0740 Fax: 913-831-9271

Strany 2 - TABLE OF CONTENTS

ON SITE STORAGE RECOMMENDATIONS (continued)IX. Butterfly (Wafer Valve)1. All limit switches, solenoids, and air cylinder ports must be capped and tape

Strany 3 - OPERATION PRINCIPLE

SETTING UP YOUR UNIT CAMCORP dust collectors are shipped in various states of assembly depending on the size and configuration of the unit. Before at

Strany 4

Platform Installation: The platform, ladder, handrail, and bracing are to be installed as shown on the special platform detail provided. Use the part

Strany 5

TOP LOAD BAG AND CAGE INSTALLATION 1. Inspect the cage for any signs of damage, warping, bent wires, or missingwelds.2. Inspect the filter bag for any

Strany 6

PRODUCT HIGHLIGHTBEADED SNAPBAND FILTER BAG DESIGN FOR FLAT TUBESHEET HOLEThe snapband was developed to improve sealing efficiency. This design elimin

Strany 7 - INSPECTION OF UNIT

START-UP CHECKLIST 1. InstallationMake sure the unit is secured to grade. The ladder(s) and platform(s) must betightened and set up according to OSHA

Strany 8

START-UP DUST CONTROL SYSTEMS1. Fan or blower systemA. Start the fan or blower and check rotation.B. Check dust pickup points for proper suction; ba

Strany 9

G. Observe the manometer or magnahelic differential pressure gauge reading. As the new filter bags become coated with dust, the efficiency of the filt

Strany 10 - 31-0740 Fax: 913-831-9271

SHUT-DOWN PROCEDURES 1. Dust control systemsReverse start-up procedure, shut down fan, then after 5 or 10 minute delay, shutdown the reverse air fan a

Strany 11 - SETTING UP YOUR UNIT

TROUBLESHOOTING THE DUST COLLECTOR I. Excessive pressure drop across filter bags The differential pressure gauge or manometer on your dust collector s

Strany 12 - Phone: 9

TABLE OF CONTENTS OPERATING PRINCIPLE & SECTION/PARTS DETAIL... 1-1 RECEIVING & INSPECTION OF UNIT...

Strany 13

TROUBLESHOOTING THE DUST COLLECTOR (continued) Visually inspect the bags for heavy caking; if caking is evident, see the note below and take the neces

Strany 14 - PRODUCT HIGHLIGHT

TROUBLESHOOTING THE DUST COLLECTOR (continued) II. Extremely Low Pressure DropA. Pressure GaugeCheck the differential pressure gauge or manometer and

Strany 15 - START-UP CHECKLIST

TROUBLESHOOTING THE DUST COLLECTOR (continued) B. Residual Dust If dust has gotten into the clean air plenum because of a dropped or torn bag, hole in

Strany 16 - START-UP DUST CONTROL SYSTEMS

TROUBLESHOOTING THE CLEANING MECHANISM 1. Fan - If the fan is not operating properly please refer to the New York Blowermanual located in this IOM man

Strany 17

SAFETY RECOMMENDATIONS Because this unit may be under pressure, do not attempt to open any device doors or panels while fans or blowers are running. I

Strany 18 - SHUT-DOWN PROCEDURES

ROUTINE MAINTENANCE A. Inspection Frequency will vary as widely as there are operating conditions. In general proceed as follows: 1. Daily – Check un

Strany 19

Center Distances1.33, 1.54, 1.75, 2.06, 2.37, 2.62, 3.00, 3.253.75, 4.50, 5.16 and 6.00®Emerson Power TransmissionP O Box 687MAYSVILLE, KY 41056Phone:

Strany 20

2© Emerson Power Transmission Manufacturing, L.P. or affiliates 2003. All Rights Reserved.TO CHANGE OUTPUT SHAFT DIRECTIONTo change the hand of a unit

Strany 21

3© Emerson Power Transmission Manufacturing, L.P. or affiliates 2003. All Rights Reserved.Figure 3 Figure 4Figure 1 Figure 2Sheet Metal Screws3. High

Strany 22

4© Emerson Power Transmission Manufacturing, L.P. or affiliates 2003. All Rights Reserved.D. Work seal loose. Be careful to keep all metal or dirt par

Strany 23

OPERATION PRINCIPLE A. Solids laden air or gases enter the unit at the hopper or housing inlet. B. Air passes through the filter media. C. Solids a

Strany 24 - SAFETY RECOMMENDATIONS

5© Emerson Power Transmission Manufacturing, L.P. or affiliates 2003. All Rights Reserved.Disconnect all power before adjusting unitsLubricate Bearing

Strany 25 - ROUTINE MAINTENANCE

6© Emerson Power Transmission Manufacturing, L.P. or affiliates 2003. All Rights Reserved.1/6 OF FACEWIDTHCLEAR ONENTERING SIDE1/31/31/3IDEALRUNS FROM

Strany 26 - Phone: 800-626-2093

MartinSPROCKET & GEAR, INC.BULLETIN TL-1TORQUE LIMITER CLUTCHDRIVE OVERLOAD PROTECTIONNow in Stock at All MartinFacilitiesAlso Stock Plate Sprocke

Strany 27 - )sbL.tF(

MartinTORQUE-LIMITERclutch offers thrifty overload protectionthat’s easy to adjust.Here is low cost protection for your machinery . . . a torquelimiti

Strany 28 - 3.75 C.D. through 6.00 C.D.:

3Torque-LimiterClutchesStock Plate Sprockets with GroundFace and Bored to Fit the MartinTorque LimiterSprocket Size35TTA25-2535TTA26-2540TTA20-2540TT

Strany 29

7CouplingSafetyWARNING & SAFETYREMINDERSafety must be considered a basic factor in machinery operation at all times. Most accidentsare the result

Strany 30 - 3.75 through 6.00 C.D.:

A WORD ABOUT SAFETYThe above WARNING decal appears on all nyb fans. Air movingequipment involves electrical wiring, moving parts, sound, andair veloc

Strany 31 - Emerson Power Transmission

HANDLING AND STORAGEFans should be lifted by the base, mounting supports, or liftingeyes only. Never lift a fan by the wheel, shaft, motor, motorbrack

Strany 32 - MartinFacilities

3. Belts tend to stretch somewhat after installation. Rechecktension after several days of operation. Check sheavealignment as well as setscrew and/or

Strany 33 - MartinTORQUE-LIMITER

Table 1 - WHEEL SETSCREW TORQUESSetscrew Size Carbon Steel Setscrew Torque*Diameter (in.) lb.-in. lb.-ft.1/2 600 505/8 -- 973/4 -- 168* Stainless Ste

Strany 35 - Coupling

COMMON FAN PROBLEMSLubrication Use the table for relubrication scheduling according to operat-ing speed and shaft diameter. Bearings should be lubrica

Strany 36 - TYPE HP PRESSURE BLOWERS

SPECIFY ROTATION AS VIEWED FROM DRIVE SIDEParts List1. Inlet Plate Assembly2. Wheel*3. Housing*4. Pedestal Assembly5. Motor6. Shaft7. Bearings* Order

Strany 37

CAMCORP, INC.Phone 913-831-0740 iFax 913-831-9271 Camcorp Reverse Air Components Item Quantity Description 1A 1 Sweep Arm (Size Determined by Unit)

Strany 39 - WHEEL-INLET CLEARANCE

RECEIVING YOUR UNITPrior to accepting shipment, care must be taken to inspect all equipment received both for proper count and for damage. Any and al

Strany 40 - 15/16 4-6 4-6 2-4 2 1-2

ON SITE STORAGE RECOMMENDATIONS I. Baghouse and Housing 1. Housing can be stored outside.2. Equipment must be blacked up to keep the flanges out of t

Strany 41 - Printed in U.S.A

ON SITE STORAGE RECOMMENDATIONS (continued)IV. Fan and Fan Accessories1. Fans can be stored outside on a pallet or skid to keep out of water and dirt.

Komentáře k této Příručce

Žádné komentáře